Simplex 4090-9117 Addressable Power Isolator – Loop Power Protection for Simplex Commercial Fire Alarm Systems

$105.00

Specifications

The 4090-9117 Simplex Addressable Power Isolator is a loop-powered module designed to isolate faults in fire alarm power circuits while ensuring uninterrupted system operation.

  • Model: 4090-9117 Addressable Power Isolator
  • Type: Addressable Power Isolator Module
  • Communication: IDNet signaling
  • Function: Short circuit and earth fault isolation
  • Ports: Dual-port, bi-directional
  • Addressing: DIP switch configurable (1–250 range)
  • Power Rating: Up to 2 A at 32 VDC
  • Mounting: Standard 4” square electrical box
  • Wiring: Supports Class A and Class B configurations
  • Indication: LED communication indicator
  • Operating Temperature: 0°C to 49°C
  • Humidity: Up to 93% RH (non-condensing)
  • Compatibility: Simplex 4007ES, 4010ES, 4100ES, 4100U panels

10 in stock

Only 10 items left in stock!

 

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

Simplex 4090-9117 Addressable Power Isolator – Loop Power Protection for Simplex Commercial Fire Alarm Systems
Simplex 4090-9117 Addressable Power Isolator – Loop Power Protection for Simplex Commercial Fire Alarm Systems
$105.00

4090-9117 Simplex Addressable Power Isolator

The 4090-9117 Simplex Addressable Power Isolator is designed to enhance the reliability and protection of fire alarm system power circuits by isolating short circuits and earth faults. It ensures that faults in one section do not impact the entire system, allowing unaffected areas to continue operating normally. Using IDNet communication, the 4090-9117 Simplex Addressable Power Isolator provides precise monitoring and control while maintaining seamless integration with advanced Simplex fire alarm panels. Its compact design, automatic fault isolation, and real-time diagnostics make it an essential component for maintaining uninterrupted fire safety performance in complex installations.

Features

  • Provides automatic isolation of short circuits and earth faults to protect system power circuits
  • Supports dual-port, bi-directional communication for flexible wiring design
  • Compatible with IDNet communication for real-time monitoring and control
  • Enables manual isolation via fire alarm control panel for diagnostics
  • Includes LED status indicator for communication and fault visibility
  • Supports Class A and Class B wiring configurations for installation flexibility
  • Designed to maintain operation of unaffected circuit sections during faults

Benefits

The 4090-9117 Simplex Addressable Power Isolator plays a crucial role in maintaining system stability by preventing complete shutdowns caused by wiring faults. It isolates only the affected section, allowing the rest of the fire alarm system to function without interruption. This reduces downtime and enhances safety in critical environments. The module also simplifies troubleshooting by enabling quick fault identification through panel diagnostics. Its dual-port design provides flexible installation options, while the loop-powered operation eliminates the need for additional power wiring, reducing installation complexity and cost.

Why Choose QuickShipFire?

  • Immediate availability of 4090-9117 Simplex Addressable Power Isolator for power circuit protection
  • Reliable sourcing ensures accurate isolator performance for IDNet-based systems
  • Expert guidance for selecting power isolators based on circuit protection requirements
  • Fast dispatch to support urgent maintenance and fault-recovery situations
  • Focus on delivering critical system protection modules for uninterrupted fire safety operations
What is the main purpose of the 4090-9117 Simplex Addressable Power Isolator?
The 4090-9117 Simplex Addressable Power Isolator protects fire alarm power circuits by isolating short circuits and earth faults without affecting the entire system.
How does the 4090-9117 Simplex Addressable Power Isolator improve system reliability?
The 4090-9117 Simplex Addressable Power Isolator ensures that only the faulty section is disconnected, allowing the remaining system to operate normally.
Can the 4090-9117 Simplex Addressable Power Isolator be controlled from the panel?
Yes, the 4090-9117 Simplex Addressable Power Isolator allows manual isolation and diagnostics directly from the fire alarm control panel.
What type of wiring configurations are supported by the 4090-9117 Simplex Addressable Power Isolator?
The 4090-9117 Simplex Addressable Power Isolator supports both Class A and Class B wiring configurations for flexible installation.
How is addressing configured in the 4090-9117 Simplex Addressable Power Isolator?
The 4090-9117 Simplex Addressable Power Isolator uses DIP switch addressing to assign a unique ID within the system.
Does the 4090-9117 Simplex Addressable Power Isolator require external power?
The 4090-9117 Simplex Addressable Power Isolator is loop-powered through IDNet communication, eliminating the need for separate power wiring.
What happens after a fault is cleared in the 4090-9117 Simplex Addressable Power Isolator?
The 4090-9117 Simplex Addressable Power Isolator automatically reconnects the circuit once the fault is resolved, restoring normal system operation.