AOM-2SF Addressable Supervised Relay Control Module – Notification Appliance Circuit Output for Hochiki Fire Alarm Systems

$105.00

Specifications

The AOM-2SF Addressable Relay Supervised Control Module is an addressable output module designed to control and supervise notification circuits with high reliability in fire alarm systems.

  • Model: AOM-2SF Addressable Relay Supervised Control Module
  • Type: Addressable Supervised Control Module
  • Function: Switching and supervision of NAC circuits
  • Communication: Addressable (Velociti protocol compatible)
  • Wiring Options: Class A (Style Z) / Class B (Style Y)
  • Output Capability: External power switching up to 80 VRMS
  • Status Monitoring: Normal, Open, Short circuit detection
  • LED Indication: Bi-color LED (green polling / red alarm)
  • Operating Voltage: 15–32 VDC
  • Mounting: Standard 4” square electrical box
  • Operating Temperature: 0°C to 49°C
  • Humidity: 10%–93% non-condensing
  • Compatibility: E3 Series, S3 Series, 7100 Series fire alarm panels

10 in stock

Only 10 items left in stock!

 

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

AOM-2SF Addressable Supervised Relay Control Module – Notification Appliance Circuit Output for Hochiki Fire Alarm Systems
AOM-2SF Addressable Supervised Relay Control Module – Notification Appliance Circuit Output for Hochiki Fire Alarm Systems
$105.00

AOM-2SF Addressable Relay Supervised Control Module

The AOM-2SF Addressable Relay Supervised Control Module is a high-performance output module designed to control notification appliance circuits (NAC) within addressable fire alarm systems. It enables the fire alarm control panel to switch external power sources such as DC supplies or audio amplifiers to activate horns, strobes, and other signaling devices. The AOM-2SF Addressable Relay Supervised Control Module also provides full supervision of the connected circuit, ensuring that faults such as open or short conditions are immediately reported to the panel. Its reliable performance and advanced communication capabilities make it ideal for critical fire alarm applications requiring controlled and monitored outputs.

Features

  • Provides supervised control of notification appliance circuits (NAC)
  • Allows switching of external power supplies or audio amplifiers (up to 80 VRMS)
  • Supports Class A (Style Z) and Class B (Style Y) wiring configurations
  • Includes bi-color LED indicator for status and diagnostics
  • Ensures real-time reporting of normal, open, and short circuit conditions
  • Uses advanced addressable communication protocol for faster response
  • Designed for installation in standard 4” square electrical boxes

Benefits

The AOM-2SF Addressable Relay Supervised Control Module enhances fire alarm system reliability by ensuring that notification circuits are continuously monitored for faults. It allows controlled activation of external devices, ensuring that alarms and signaling appliances function correctly during emergencies. The supervised operation reduces the risk of undetected wiring issues, improving overall system safety. Its support for both Class A and Class B wiring provides flexibility in system design, while the ability to switch external power sources makes it suitable for large-scale installations. Additionally, its fast communication response ensures timely activation of notification devices during critical events.

Why Choose QuickShipFire?

  • Immediate availability of AOM-2SF modules for supervised NAC control applications
  • Trusted sourcing ensures accurate performance in notification circuit control systems
  • Expert support for selecting modules for external power switching and alarm activation
  • Fast dispatch for urgent fire alarm installation and maintenance needs
  • Focus on delivering advanced supervised control modules for reliable system operation
What is the function of the AOM-2SF Addressable Relay Supervised Control Module?
The AOM-2SF Addressable Relay Supervised Control Module is used to control and supervise notification appliance circuits in a fire alarm system.
What type of devices can the AOM-2SF Addressable Relay Supervised Control Module control?
The AOM-2SF Addressable Relay Supervised Control Module controls devices such as horns, strobes, and other notification appliances powered by external sources.
How does the AOM-2SF Addressable Relay Supervised Control Module improve system safety?
The AOM-2SF Addressable Relay Supervised Control Module continuously monitors wiring conditions and reports faults like open or short circuits to the panel.
What wiring configurations are supported by the AOM-2SF Addressable Relay Supervised Control Module?
The AOM-2SF Addressable Relay Supervised Control Module supports both Class A (Style Z) and Class B (Style Y) configurations.
Does the AOM-2SF Addressable Relay Supervised Control Module support external power switching?
Yes, the AOM-2SF Addressable Relay Supervised Control Module can switch external DC power supplies or audio amplifiers up to 80 VRMS.
How is the status of the AOM-2SF Addressable Relay Supervised Control Module indicated?
The AOM-2SF Addressable Relay Supervised Control Module uses a bi-color LED to indicate communication and alarm status.
Why is the AOM-2SF Addressable Relay Supervised Control Module important in fire alarm systems?
The AOM-2SF Addressable Relay Supervised Control Module ensures reliable activation and supervision of notification circuits, which is critical for effective emergency alerts.