The AMM-4F Addressable Monitor Module is a four-circuit monitoring device designed to integrate multiple conventional initiating devices into addressable fire alarm systems with accurate supervision and fast communication.

  • Model: AMM-4F Addressable Monitor Module
  • Type: Addressable Multi-Circuit Monitor Module
  • Circuits: Four Style B (Class B IDC circuits)
  • End-of-Line Resistor: 47kΩ per circuit
  • Communication: Addressable protocol compatible
  • Addressing: Rotary switch (multi-address support for each circuit)
  • LED Indication: Bi-color LEDs for each circuit
  • Operating Voltage: 15–32 VDC
  • Mounting: Standard 4” square electrical box
  • Operating Temperature: 0°C to 49°C
  • Humidity: 10%–93% non-condensing
  • Compatibility: E3 Series, S3 Series, 7100 Series fire alarm panels

1 in stock

Only 1 items left in stock!

 

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

AMM-4F Addressable Monitor Module – Class A/B Wiring Initiating Device Interface for Hochiki Fire Alarm Systems
AMM-4F Addressable Monitor Module – Class A/B Wiring Initiating Device Interface for Hochiki Fire Alarm Systems
$125.00

AMM-4F Addressable Monitor Module

The AMM-4F Addressable Monitor Module is a high-capacity interface device designed to monitor up to four independent initiating device circuits within an addressable fire alarm system. It allows multiple conventional devices such as manual pull stations, waterflow switches, tamper switches, and heat detectors to be integrated efficiently into a single module. The AMM-4F Addressable Monitor Module uses advanced communication protocols to ensure fast and accurate signal transmission to compatible fire alarm control panels. Its multi-circuit capability makes it ideal for large installations where space optimization, reduced wiring, and efficient monitoring are essential.

Features

  • Supports four independent Style B (Class B) initiating device circuits
  • Converts normally open dry contact devices into addressable inputs
  • Enables multi-zone monitoring using a single module
  • Equipped with bi-color LED indicators for status and diagnostics
  • Uses rotary switch addressing for quick and easy configuration
  • Reduces hardware requirements by combining multiple circuits into one device
  • Designed for high-efficiency monitoring in large fire alarm systems

Benefits

The AMM-4F Addressable Monitor Module significantly improves system efficiency by allowing four separate circuits to be monitored using a single device, reducing installation time and overall hardware costs. It optimizes panel address usage while maintaining accurate supervision of each circuit. This module is especially useful in large facilities where multiple zones need to be monitored from a centralized point. Its compact design reduces wiring complexity and simplifies installation, while advanced communication ensures quick detection of alarms and faults. Additionally, it enhances scalability, making it easier to expand fire alarm systems without adding excessive modules.

Why Choose QuickShipFire?

  • Reliable availability of AMM-4F modules for multi-circuit monitoring applications
  • Trusted sourcing ensures consistent performance across all four monitoring circuits
  • Expert support for selecting high-capacity modules for large-scale installations
  • Fast dispatch for time-sensitive fire alarm projects and upgrades
  • Focus on delivering efficient multi-zone monitoring solutions for advanced systems
What is the function of the AMM-4F Addressable Monitor Module?
The AMM-4F Addressable Monitor Module is used to monitor four independent initiating device circuits within an addressable fire alarm system.
How many circuits can the AMM-4F Addressable Monitor Module handle?
The AMM-4F Addressable Monitor Module supports four separate Class B initiating device circuits.
What types of devices can be connected to the AMM-4F Addressable Monitor Module?
The AMM-4F Addressable Monitor Module supports devices such as pull stations, waterflow switches, tamper switches, and heat detectors with dry contacts.
How does the AMM-4F Addressable Monitor Module improve installation efficiency?
The AMM-4F Addressable Monitor Module reduces the number of modules required by combining four circuits into a single device.
How is addressing configured in the AMM-4F Addressable Monitor Module?
The AMM-4F Addressable Monitor Module uses rotary switches to assign addresses for each monitored circuit.
Is the AMM-4F Addressable Monitor Module suitable for large fire alarm systems?
The AMM-4F Addressable Monitor Module is ideal for large installations where multiple zones need to be monitored efficiently.
How does the AMM-4F Addressable Monitor Module ensure reliable monitoring?
The AMM-4F Addressable Monitor Module uses supervised circuits with end-of-line resistors to detect faults and maintain accurate system status.