4098-9754 Simplex TrueAlarm Multi-Sensor Fire Detector – Addressable Photoelectric + Heat Combo Detector for Commercial Buildings

$95.00

Specifications

The 4098-9754 is a Simplex multi-sensor fire detector that combines smoke and heat sensing with intelligent signal processing for sharply higher accuracy and reduced nuisance alarms vs single-technology detectors.

  • Model: 4098-9754 Multi-Sensor Fire Detector
  • Brand: Simplex
  • Type: Multi-sensor addressable fire detector
  • Detection Methods: Combined smoke and heat sensing
  • Signal Processing: Intelligent cross-verification
  • System Compatibility: Addressable fire alarm systems
  • Power Source: Panel-powered
  • Indicators: LED status
  • Installation: Ceiling-mounted with standard base
  • Typical Applications: Commercial, industrial, institutional
  • Nuisance-Alarm Profile: Reduced vs single-sensor types
  • Service: Head-replaceable, addressable point preserved in base

20 in stock

Only 20 items left in stock!

 

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

4098-9754 Simplex TrueAlarm Multi-Sensor Fire Detector – Addressable Photoelectric + Heat Combo Detector for Commercial Buildings
4098-9754 Simplex TrueAlarm Multi-Sensor Fire Detector – Addressable Photoelectric + Heat Combo Detector for Commercial Buildings
$95.00

4098-9754 Multi-Sensor Fire Detector

The 4098-9754 Multi-Sensor Fire Detector is an advanced fire detection device engineered to deliver accurate and reliable performance in demanding environments. By combining multiple sensing technologies, it enhances detection capability while significantly reducing false alarms. Designed for seamless integration with addressable systems, it ensures fast response and improved safety across commercial and industrial applications.

Features

  • Multi-sensor technology combining smoke and heat detection for improved accuracy
  • Intelligent signal processing to minimize nuisance alarms
  • Compatible with addressable fire alarm control panels
  • LED status indicators for easy monitoring and maintenance
  • Durable construction designed for long-term reliability
  • Quick and secure installation with standard mounting bases
  • Continuous environmental monitoring for enhanced safety response

Benefits

The 4098-9754 Multi-Sensor Fire Detector provides enhanced fire protection by utilizing both smoke and heat sensing technologies. This combination allows early detection of various fire types, improving response time and overall safety. Its intelligent design helps reduce false alarms, which is especially important in environments where operational continuity is critical.

The detector also simplifies installation and maintenance, reducing labor time and costs. Its addressable functionality enables precise identification of alarm locations, allowing faster emergency response. With its durable construction and consistent performance, it offers a reliable and long-term fire safety solution.

Why Choose QuickShipFire?

  • Access to the 4098-9754 Multi-Sensor Fire Detector with assured product authenticity
  • Fast availability for projects requiring advanced multi-sensor detection solutions
  • Reliable sourcing of addressable detectors compatible with modern fire systems
  • Support in selecting the right multi-sensor technology for complex environments
  • Efficient delivery to meet urgent commercial and industrial safety requirements
How does the 4098-9754 decide when to alarm?
The panel applies intelligent cross-verification: smoke-sensor trends are weighed against heat-sensor trends, so a concurrent rise in both raises alarm confidence and a smoke-only signal without heat gets discriminated more carefully.
Is the 4098-9754 suitable for sleeping rooms?
It can be deployed in sleeping rooms; for in-room audible alerting on alarm, pairing with a sounder base (like the 4098-9794) or nearby notification appliance is typically required by code.
Can the 4098-9754 replace an existing 4098-9714 photoelectric detector?
Often yes, for spaces with recurring nuisance-alarm history, swapping a 4098-9714 for a 4098-9754 on the existing base is a common mitigation strategy; compatibility of base and panel protocol should be confirmed.
Does the multi-sensor design require a special base?
The 4098-9754 mounts on compatible addressable bases; specific base compatibility should be verified against current Simplex documentation before ordering.
Is response time slower than a pure photoelectric detector?
No meaningful difference in real-world fire response the cross-verification operates quickly at the panel, preserving fast alarm speed while improving discrimination against nuisance events.
Does the detector report which sensor (smoke or heat) triggered the alarm?
Reporting depth depends on the host panel's programming some configurations log individual sensor contributions, which can be useful for post-event investigation and nuisance-alarm analysis.
When is a multi-sensor detector overkill versus a single-sensor type?
For clean, stable office environments with no nuisance-alarm history, a pure photoelectric detector is often sufficient; multi-sensor becomes valuable in environments with intermittent dust, steam, or transient alarm triggers.