4090-9101 IDNet/MAPNET II Monitor ZAM

$95.00

Specifications

The 4090-9101 IDNet/MAPNET II Monitor ZAM is a zone adapter module designed to monitor conventional fire detection circuits while providing addressable communication and supervision.

  • Model: 4090-9101 Monitor ZAM
  • Type: Zone Adapter Module (ZAM)
  • Communication: IDNet / MAPNET II
  • Function: Monitor conventional IDC (2-wire / 4-wire devices)
  • Input Voltage: 18–32 VDC (Nominal 24 VDC)
  • Current Consumption: Up to 16 mA (supervisory), 72 mA (alarm)
  • Addressing: DIP switch configurable (IDNet up to 250, MAPNET II up to 127)
  • Wiring Distance: Up to 2500 ft from control panel
  • Mounting: Standard 4” square electrical box
  • Enclosure: Black thermoplastic housing
  • Operating Temperature: 0°C to 49°C
  • Humidity: Up to 93% RH (non-condensing)

Out of stock

 

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

4090-9101 IDNet/MAPNET II Monitor ZAM
4090-9101 IDNet/MAPNET II Monitor ZAM
$95.00

4090-9101 IDNet/MAPNET II Monitor ZAM

The 4090-9101 IDNet/MAPNET II Monitor ZAM is a highly efficient zone adapter module designed to integrate conventional initiating device circuits into modern addressable fire alarm systems. It enables a single addressable point to monitor an entire conventional zone consisting of 2-wire or 4-wire devices such as smoke detectors, heat detectors, and pull stations. Built for seamless compatibility with IDNet and MAPNET II communication protocols, the 4090-9101 IDNet/MAPNET II Monitor ZAM ensures accurate status reporting and system supervision. Its compact and durable design, combined with flexible installation options, makes it a reliable choice for expanding or upgrading fire alarm systems.

Features

  • Converts conventional initiating device circuits into addressable zones for better system control
  • Supports 2-wire and 4-wire initiating devices with power reset capability
  • Compatible with IDNet and MAPNET II communication systems
  • Provides multi-state status reporting including normal, open, alarm, and fault conditions
  • Includes LED indicator for communication status and diagnostics
  • Designed with sealed thermoplastic housing to minimize dust and environmental impact
  • Easy installation using standard 4-inch electrical box mounting

Benefits

The 4090-9101 IDNet/MAPNET II Monitor ZAM simplifies the integration of legacy or conventional detection devices into modern addressable fire alarm systems. It reduces the need for complete system replacement by allowing existing devices to operate within an intelligent network. The module enhances system efficiency by grouping multiple devices under a single address, saving valuable address space. Its advanced supervision capabilities help detect faults such as open circuits or short conditions quickly, improving system reliability. Additionally, the ability to support both 2-wire and 4-wire devices makes it highly versatile for different installation requirements, ensuring cost-effective upgrades and expansions.

Why Choose QuickShipFire?

  • Dedicated supply of 4090-9101 Monitor ZAM for zone integration and retrofit projects
  • Trusted sourcing ensures accurate compatibility with both IDNet and MAPNET II systems
  • Expert assistance for selecting zone modules for mixed conventional and addressable setups
  • Fast delivery support for urgent fire alarm upgrades and maintenance needs
  • Focus on providing reliable monitoring modules for system expansion without full replacement

FAQs

What does the 4090-9101 IDNet/MAPNET II Monitor ZAM do in a fire alarm system?
The 4090-9101 IDNet/MAPNET II Monitor ZAM allows conventional detection devices to be connected and monitored within an addressable fire alarm system.
Can the 4090-9101 IDNet/MAPNET II Monitor ZAM support multiple devices on one zone?
Yes, the 4090-9101 IDNet/MAPNET II Monitor ZAM can monitor an entire conventional circuit with multiple initiating devices under a single address.
How does the 4090-9101 IDNet/MAPNET II Monitor ZAM report faults?
The 4090-9101 IDNet/MAPNET II Monitor ZAM provides multi-state reporting, including open, short, and alarm conditions for accurate system diagnostics.
What type of detectors work with the 4090-9101 IDNet/MAPNET II Monitor ZAM?
The 4090-9101 IDNet/MAPNET II Monitor ZAM supports both 2-wire and 4-wire detectors, including smoke and heat detectors.
How is addressing configured in the 4090-9101 IDNet/MAPNET II Monitor ZAM?
The 4090-9101 IDNet/MAPNET II Monitor ZAM uses an onboard DIP switch system to assign a unique address within the fire alarm network.
Does the 4090-9101 IDNet/MAPNET II Monitor ZAM help in system upgrades?
Yes, the 4090-9101 IDNet/MAPNET II Monitor ZAM is ideal for upgrading conventional systems by integrating them into addressable networks.
What makes the 4090-9101 IDNet/MAPNET II Monitor ZAM efficient for large systems?
The 4090-9101 IDNet/MAPNET II Monitor ZAM reduces address usage by grouping multiple devices into one monitored zone, improving scalability.