  • Model: SD500-SDM Addressable Smoke Detector Module
  • Type: Addressable 2-wire smoke detector interface module
  • Input Type: 2-wire smoke detector loop
  • Zone Capacity: Multiple detectors per loop
  • Power Supply: 24V DC auxiliary input
  • Connection: Signaling Line Circuit (SLC) loop
  • Addressing: DIP switch programmable
  • Function: Converts conventional loop into addressable point
  • Wiring Style: Class A / Class B compatible
  • Supervision: Full circuit monitoring for faults and alarms
  • Compatibility: Silent Knight IntelliKnight fire alarm panels

2 in stock

Only 2 items left in stock!

 

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

SD500-SDM Addressable Smoke Detector Module – Conventional 2-Wire Smoke Detector Zone Interface for Silent Knight Fire Systems
SD500-SDM Addressable Smoke Detector Module – Conventional 2-Wire Smoke Detector Zone Interface for Silent Knight Fire Systems
$295.00

SD500-SDM Addressable Smoke Detector Module

The SD500-SDM Addressable Smoke Detector Module is built for projects where conventional smoke detection needs to be integrated into an intelligent fire alarm system without replacing existing devices. It enables a loop of 2-wire smoke detectors to function as a single addressable point, allowing the control panel to monitor an entire detection zone efficiently.

This module plays a key role in retrofit and hybrid installations, where upgrading infrastructure must be done without major disruption. By converting a conventional detection loop into an addressable interface, it ensures that existing smoke detectors remain functional while benefiting from modern system monitoring and control.

Features

Instead of focusing only on connectivity, this module enhances how conventional smoke detection behaves within an addressable system:

  • Converts a full 2-wire smoke detector loop into one addressable point
  • Supports multiple detectors within a single monitored circuit
  • Works with both Class A and Class B configurations for different system layouts
  • Designed for stable operation across varying installation environments
  • DIP switch configuration allows quick and accurate addressing
  • Reduces commissioning time during installation
  • Continuously monitors the loop for faults, alarms, and wiring issues
  • Ensures reliable performance in critical safety applications

Benefits

In real-world fire alarm upgrades, replacing every smoke detector can be costly and time-consuming. The SD500-SDM Addressable Smoke Detector Module eliminates that challenge by allowing entire zones of conventional detectors to remain in service while still being monitored through an addressable system.

For contractors, this means faster installation and reduced labor. For facility owners, it significantly lowers upgrade costs while still improving system intelligence. The module also ensures better visibility of detection zones at the panel level, enabling quicker identification of alarm conditions without redesigning the entire system.

Why Choose QuickShipFire?

  • Availability of SD500-SDM modules for smoke detection zone integration
  • Access to genuine modules for hybrid and retrofit fire alarm systems
  • Support in selecting zone-based solutions for conventional detector reuse
  • Fast dispatch for projects requiring quick system upgrades
  • Focus on delivering modules that reduce upgrade cost while improving system capability
In which situations is the SD500-SDM Addressable Smoke Detector Module most effective?
The SD500-SDM Addressable Smoke Detector Module is ideal when upgrading systems while keeping existing 2-wire smoke detectors in operation.
How many detectors can be connected using the SD500-SDM Addressable Smoke Detector Module?
The SD500-SDM Addressable Smoke Detector Module supports multiple detectors within a single loop, depending on system design.
Does the SD500-SDM Addressable Smoke Detector Module require separate power?
Yes, the SD500-SDM Addressable Smoke Detector Module uses a 24V DC auxiliary power supply to operate the detector loop.
Can the SD500-SDM Addressable Smoke Detector Module be used in both new and old buildings?
The SD500-SDM Addressable Smoke Detector Module is suitable for both new installations and retrofit projects.
What type of wiring flexibility does the SD500-SDM Addressable Smoke Detector Module offer?
The SD500-SDM Addressable Smoke Detector Module supports both Class A and Class B wiring configurations.
How does the SD500-SDM Addressable Smoke Detector Module improve system monitoring?
The SD500-SDM Addressable Smoke Detector Module allows an entire detector loop to be monitored as an addressable point at the control panel.
Why is the SD500-SDM Addressable Smoke Detector Module preferred in hybrid systems?
The SD500-SDM Addressable Smoke Detector Module enables seamless integration of conventional detectors into modern addressable systems.